High-performance CT PT Analyzer solution, available from Myriad Industrial Solutions LLP at the best price for global industrial and utility testing. Efficient CT PT Analyzer crafted for precision transformer diagnostics, brought to you by Myriad Industrial Solutions LLP at the best rate for commercial electrical infrastructures. CT PT Analyzer conducts examinations based on excitation characteristics, transformation ratio, polarity, demagnetize, and 5 and 10 error curves, while conducting a secondary circuit check. The CT PT Analyzers withstand power frequency tests for alternating current and secondary load.
Functions for Testing
Functions for Testing PT
Applications: Widely used in the power distribution and transformer manufacturing industries.
Analyzer Features:
| Test Standards: | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, IEC60044-61869, GB-1207, GB1208, GB-16849, C57.13 |
| Power Supply: | AC220V±10%, 50/60Hz±10% |
| Voltage Output: | 0.1~160V AC(AC 0-4KV With External Voltage Booster) |
| Current Output: | 0.001~5A(RMS), Peak Value 15A |
| Power Output: | 500VA |
| Maximum Knee Voltage Measurement | Maximum Knee Voltage Measurement |
| Current Measurement Range | 0~10A (automatically Change Range In 0.004/0.04/0.4/2/10A Auto Range) Error: <±0.1%+0.01%FS |
| Voltage Measurement Range | 0~200V (automatically Change Range In 1V/10V/120V/240V Auto Range) Error: < ±0.1%+0.01%FS |
| Turns Ratio Measurement | Range:1~35000 1~2000 Error<0.05% 2000~5000 Error<0.1% 5000~35000 Error<0.2% |
| Ratio Error Of CT | Typical <0.02%, Assured <0.1%, Resolution <0.01% |
| Phase Measurement | Error < 2min; Resolution: 0.01min |
| Winding Resistance Measurement | Range: 0~10kΩ (automatically Change Range In 2ohm/20ohm/160ohm/1kohm/10kohm Auto Range) Error: < 0.2%RDG+0.02%FS Maximum Resolution: 0.1Mω |
| Temperature Measurement | 50~100 Celsius Degree; Error<3 Celsius Degree ‘ |
| CT Secondary Burden Range | 0 -160ohm (automatically Change Range In 2ohm/20ohm/160ohm Auto Range) Error: <0.2%RDG+0.02%FS Maximum Resolution: 0.001ohm |
| PT Secondary Burden And Admittance Test | Burden Range: 80kohm (automatically Change Range In 320ohm/5.3kohm/80kohm Auto Range) |
| Admittance Range | 0-100mS Error :<0.2%RDG+0.02%FS Maximum Resolution: 0.1ohm |
| PT Ratio Measurement | Range: 1~30000 1~2000 Error<0.1% 2000~10000 Error<0.2% 10000~30000 Error<0.5% With 4KV Voltage Booster: 1-2200 Error <0.05% |
| VT Ratio Error Measurement | Phase Error <30min, Resolution 0.1min 17) VT Excitation Mode Ratio Error Measurement. Ratio Error <0.1%, Phase Error<3min |
| CVT Ratio Measurement | 1-2200 Error< 0.05%(with 4kv Voltage Booster Only) |